Leave Your Message
Ngā Kāwai Pūrongo
Ngā Pūrongo Matua

He aha te Whakawhitiwhiti Papa e Mau ana? Te Aratohu Katoa

2025-10-30

Whakawhitinga Whakamau PapaKo ngā PMT (s) ngā toa rongonui o te tohatoha hiko o ēnei rā. Hei wāhanga nui o ngā whatunga hiko o ngā tāone me ngā tāone iti, ka tukuna haumaru e ēnei waeine whenua iti te hiko ki ngā kāinga, ki ngā pakihi, me ngā hanganga tūmatanui. Engari he aha rawa te mea e tino hiahiatia ai rātou?

 

Te Tautuhi i ngā Whakawhitinga Whakamau Papa

He taputapu kua katihia te whakawhiti hiko e mau ana ki te papa, e mau ana ki te whenua Whakawhitinga Tohatoha Hiko kua tāutahia ki runga i tētahi papa raima. I hangaia mō te whakamahinga o waho, ka whakaheke i te hiko ngaohiko teitei (te nuinga o te 15kV-35kV) ki ngā taumata ngaohiko iti e taea te whakamahi (120V-600V) mō ngā kaihoko mutunga.

 

Ngā Wāhanga Matua:

Tāke me te Ārai

 

Whare rino ātete-huarere me ngā raka ātete-whakarerekē

 

Ngā paninga ātete-waikura mō te roanga o te ora mō te 30+ tau

 

Matua me ngā Āwhiowhio

 

Ngā matua maitai silicone me ngā takai parahi/konumohe

 

Pūnaha Whakamatao

 

Ngā hoahoa whakamatao-ā-waka (OA) me te hau-ā-pū (FA) rānei

 

Ngā pūahi

 

He hoahoa mata-mua mō te haumaru ake

 

Ngā Pūnaha Tiaki

 

Ngā taputapu whakaiti pēhanga, ngā tohu hapa, ngā aukati ngaru

 

He aha i whiriwhiri ai i ngā Whakawhitinga Whakamau Papa? 5 Ngā Painga Matua

① Hoahoa Penapena Wāhi

Mā ngā hononga taura o raro whenua me ngā tapuwae kiato (1.5mx 2m te nuinga), ka kore e hiahiatia ngā taura me ngā pou hiko o runga ake i ngā PMT - he mea tino pai mō ngā tāone kikī me ngā wāhi ātaahua.

 

② Te Haumaru ā-Iwi Whakarei Ake

Ka āraihia e ngā ārai raka te urunga kore mana

 

E tutuki ana ngā pūnaha pupuri hinu i raro i te wai i ngā whakaritenga a te EPA

 

Ka whakaitihia e te parenga o te au hapa ngā mōrearea ahi

 

③ Te Whakaiti i ngā Utu Tiaki

He 50% te iti iho o te tiaki e hiahiatia ana mō ngā PMT hou i ngā waeine pou-runga, e ai ki ngā paerewa IEEE C57.12.00, me ngā tāke kua hiritia kia ātete ki te makuku me te whakamarumaru ātete ki te haumākū.

 

④ Te Pono o te Whatunga

Mā ngā whakawhiti hiko e mau ana ki te papa ka taea ngā whirihoranga whāngai koropiko - ki te rahua tētahi waeine, ka hurihia aunoa e ngā pana whatunga te hiko hei whakaiti i te motuhanga.

 

⑤ Ngāwari Whakaritenga

Kei te wātea i roto i ngā whirihoranga wāhanga-kotahi (25-500kVA) me ngā whirihoranga wāhanga-toru (75-5,000kVA) me ngā kōwhiringa mō:

 

Whakaiti i te harmonic

 

Ngā hoahoa haruru iti (

 

Ngā tauira tino whai hua (e tutuki ana i ngā paerewa o te DOE 2023)

 

Ngā Taupānga: Te Wāhi e Whakakahangia ai ngā Hapori e ngā Whakamau Papa

Ngā whanaketanga wāhanga me ngā whare noho

 

Ngā toa hokohoko me ngā pokapū arumoni

 

Ngā puni hōhipera me ngā whare wānanga

 

Ngā papa ahumahi (me te ārai i te mura o te pewa)

 

Ngā hononga pūngao whakahou