Leave Your Message
Ngā Kāwai Pūrongo
Ngā Pūrongo Matua

Ngā Hua–Ngā Take Whakaoti

2025-07-19

I te tau 2024, i tukuna e mātou he whakawhiti hiko 12 MVA ki Philippines. Ko te mana whakatauranga o tēnei whakawhiti hiko he 12,000 KVA, ā, he whakawhiti hiko whakaheke-iho tēnei, e huri ana i te ngaohiko tuatahi o te 66 KV ki te ngaohiko tuarua o te 33 KV. Ka whakamahia e mātou te parahi mō te rauemi takai nā te mea he pai ake tōna kawe hiko, tōna pai o te wera, me tōna ātete ki te waikura.
He mea hanga ki ngā hangarau hou me ngā rauemi kounga teitei, e tuku ana tā mātou whakawhiti hiko 12 MVA i te pono me te pakari tino pai.
I JZP, ka oati mātou ka whai whakamātautau whānuitia ia whakawhiti hiko e tukuna ana e mātou. E whakahīhī ana mātou ki te pupuri i tētahi rekoata kore-hapa tino pai mō te neke atu i te tekau tau. Ko tā mātou mahi he rumaki hinu Ngā Whakawhiti Mana kua hangaia kia tutuki ai ngā paerewa pakari o IEC, ANSI, me ētahi atu whakaritenga o te ao.
 
Whānuitanga o te Tukunga
Hua: Whakawhiti Hiko Rukuhia ki te Hinu
Mana Whakatauria: Tae atu ki te 500 MVA
Ngaohiko Matua: Tae atu ki te 345 KV
 
Whakatakotoranga Hangarau
Ngā whakatakotoranga me te pepa raraunga mō te whakawhiti hiko 12 MVA

Tauira SFZ11-12 MVA-66/33KV
Momo 0il te whakawhiti hiko rumaki
Paerewa IEC60076
Mana Whakatauria 12000 KVA
Auautanga 60HZ
Wāhanga 3
Momo Whakamatao KORE I TE WHAKAMANA
Ngaohiko Tuatahi 66 KV
Ngaohiko Tuarua 33 KV
Rauemi Whakakorikori Parahi
Rōpū Wetereo Ynd1
Āraitanga 10%
Huringa Tāpā OLTC
Awhe Tātari ±8*1.25%
Ngā Taputapu Paerewa
Ngā Kōrero Kāore he

Te tikanga whakamatao o tētahi Whakawhiti Hinu-Rukuhia Ko te tikanga, ko te whakamahi i te hinu whakawhiti hiko hei reo whakamatao matua. E rua ngā mahi matua o tēnei hinu: he ārai hiko, ā, he āwhina ki te whakamarara i te wera e puta ana i roto i te whakawhiti hiko. Anei ētahi tikanga whakamatao e whakamahia ana i roto i ngā whakawhiti hiko kua rumakina ki te hinu:
1. Hinu Taiao Hau Taiao (ONAN)
● Whakaahuatanga:
I tēnei tikanga, ka whakamahia te whakawhiti hiko taiao hei huri i te hinu i roto i te tāke whakawhiti hiko.
Ka mimitihia te wera e puta mai ana i ngā takai o te whakawhiti hiko e te hinu, kātahi ka piki ake ka whakawhiti i te wera ki ngā pakitara o te tāke.
Kātahi ka marara te wera ki te hau e karapoti ana mā te whakawhiti wera ā-taiao.

● Ngā tono:
o He pai mō ngā whakawhiti hiko iti ake, ina kore e nui rawa te wera e whakaputaina ana.

● Whakaahuatanga:
He rite tēnei tikanga ki te ONAN, engari kei roto ko te tohanga hau ā-kaha.
Ka whakamahia ngā pā hau hei pupuhi i te hau ki runga i ngā mata o te radiator o te whakawhiti hiko, hei whakarei ake i te tukanga whakamatao.

● Ngā tono:
o Whakamahia i roto i ngā whakawhiti hiko rahi-waenga ina hiahiatia he whakamatao tāpiri atu i tua atu i te kawe hau maori.

● Whakaahuatanga:
I roto i te OFAF, ka tohatohahia te hinu me te hau mā te whakamahi i ngā papu me ngā pā hau.
Ka rere te hinu i roto i te whakawhiti hiko me ngā whakamahana hiko, ko ngā pā hau ka pana i te hau puta noa i ngā whakamahana hiko.

● Ngā tono:
o He pai mō ngā whakawhiti hiko nui ina kore e ranea te kawe hiko maori mō te whakamatao.

● Whakaahuatanga:
Ka whakamahia e tēnei tikanga te wai hei rauemi whakamatao tāpiri.
Ka tohatohahia te hinu mā roto i ngā whakawhiti wera, ka whakamataohia te hinu e te wai.
Kātahi ka whakamataohia te wai mā roto i tētahi pūnaha motuhake.

● Ngā tono:
oE whakamahia ana i roto i ngā whakawhiti hiko tino nui, i ngā whakaurunga rānei he iti te wāhi mō te whakamatao hau, ā, e hiahiatia ana he pai ake te whai huatanga.

● Whakaahuatanga:
He rite ki te OFAF, engari he pai ake te rere o te hinu.
Ka tukuna te hinu mā roto i ngā hongere, i ngā paipa rānei, hei whakarei ake i te whai huatanga o te whakamatao i ngā wāhi wera motuhake i roto i te whakawhiti hiko.

● Ngā tono:
o Whakamahia i roto i ngā whakawhiti hiko ina hiahiatia he whakamatao kua whakaritea hei whakahaere i te tohatoha wera kāore i te ōrite.

● Whakaahuatanga:
He tikanga whakamatao matatau tēnei e tukuna ai te hinu kia rere mā roto i ngā ara motuhake i roto i te whakawhiti hiko, kia tika ai te whakamatao.
Kātahi ka whakawhitia te wera ki te wai mā roto i ngā whakawhiti wera, me te tohanga ā-ringa kia marara pai ai te wera.

● Ngā tono:
o He mea tino pai mō ngā whakawhiti hiko nui rawa atu, mana-teitei rānei i roto i ngā tono ahumahi, tono whaipainga rānei, ina nui te whakahaere i te pāmahana tika.

2. Hinu Taiao Ā-Hau (ONAF)
3. Hinu Āwhina Ā-Hau (OFAF)
4. Hinu Āwhina Wai Āwhina (OFWF)
5. Te Whakahaunga Hinu-ā-Hau (ODAF)
6. Wai Whakahauhia e te Hinu (ODWF)