+86 18068001229 Me pēhea te whakarōpūtanga o ngā ngaohiko teitei, waenga, iti, me te tino teitei i roto i ngā pūnaha hiko?
He mea nui te whakarōpūtanga o ngā taumata ngaohiko i roto i ngā pūnaha hiko hei whakarite i te tuku hiko, te tohatoha, me te haumaru whai hua. Mā ngā taumata ngaohiko ka whakatau te kawe hiko puta noa i ngā whatunga hiko, ka whakatauritea kia rite ki te whaihua hangarau me te whaihua ōhanga, ā, ka urutau ki ngā tono kanorau. Ka tūhuratia e tēnei tuhinga ngā paearu me ngā paerewa e whakahaere ana i ēnei whakarōpūtanga, me te arotahi ki ngaohiko teitei (HV),ngaohiko waenga (MV),ngaohiko iti (LV), mengaohiko tino teitei (UHV).
1. Ngā Paearu Whakarōpūtanga Ngaohiko;
Ko ngā taumata ngaohiko te mea matua e tautuhia ana engā paerewa hiko (hei tauira, IEC, IEEE, ngā ture ā-motu) me ngā whakaritenga whakahaere, tae atu ki:
- ;Tawhiti tukuKa whakaitihia te ngaronga pūngao e ngā ngaohiko teitei ake i ngā tawhiti roa.
- ;Te kaha o te manaMā ngā ngaohiko teitei ake ka taea te whakawhiti mana nui ake.
- ;Te hoahoa taputapuKo te whakamarumaru, te whakamatao, me te pakari o te rauemi e whakawhirinaki ana ki te ahotea ngaohiko.
- ;Hanganga whatunga: Ka hāngai ngā taumata ngaohiko ki te hiranga whatunga (whakaputa → tuku → tohatoha).
;2. Ngā Whakamāramatanga Taumata Ngaohiko;
;Ngaohiko Iti (LV);
- ;Awhe: ≤1,000 V (AC) ≤1,500 V (DC) rānei.
- ;Ngā tono:
- Pūnaha hiko mō ngā whare noho me ngā whare pakihi (hei tauira, 220V/380V i Haina, 120V/240V i Amerika Te Raki).
- Ngā taputapu iti, ngā rama, me ngā mīhini ahumahi.
- ;Ngā Āhuatanga Matua:
- Ka hono tika i ngā kaiwhakamahi mutunga.
- He iti noa te whakamarumaru e hiahiatia ana nā te iti o te ahotea.
;Ngaohiko Waenga (MV);
- ;Awhe: 1 kV ki te 35 kV (ka rerekē i runga i te rohe).
- Haina10 kV–35 kV.
- Ūropi: 11 kV–20 kV.
- ;Ngā tono:
- Te tohatoha o ngā tāone iti me ngā ahumahi.
- Ngā raina whāngai e hono ana i ngā teihana hiko ki ngā whatunga LV.
- ;Ngā Āhuatanga Matua:
- Ka whakataurite i te whai huatanga me te haumaru mō te tuku reo-waenga.
- E whakamahi ana i ngā taura, i ngā raina rānei he āhua rite te whakamarumaru.
;Ngaohiko Teitei (HV);
- ;Awhe35 kV ki te 220 kV.
- ;Ngā tono:
- Te tuku kōrero ā-rohe i waenga i ngā tāone.
- Te tuku hiko nui mai i ngā tipu hiko ki ngā teihana hiko iti.
- ;Ngā Āhuatanga Matua:
- Me whai pūnaha whakamahana me te whakamatao pakari.
- Tautoko ana i te rere o te hiko i runga ake i te 100–500 km.
;Ngaohiko Tino-Teitei (UHV);
- ;ME TE UHV: ≥1,000 kV.
- ;UHV DC: ≥±800 kV.
- ;Ngā tono:
- Ngā ara hiko whakawhiti-whenua (hei tauira, te raina AC 1,100 kV o Haina).
- Tuku tawhiti, kaha nui (hei tauira, 2,000–3,000 km).
- ;Ngā Āhuatanga Matua:
- Ka whakaiti i ngā mate tuku ki te
- Ka āhei te whakaurunga o te pūngao hou (hei tauira, ngā pāmu pūngao rā i ngā koraha).
;3. Ngā Whakaaro Hangarau me ngā Whakaaro Whakahaere;
;Ngā Aratohu Kōwhiringa Ngaohiko;
- ;Ngā whakawhiti hiko-whakarungaI ngā tipu hiko, ka whakanuia te ngaohiko ki te HV/UHV mō te tuku.
- ;Ngā whakawhiti hiko-ihoKa whakaitihia te ngaohiko ki ngā teihana hiko iti ki te MV/LV mō ngā kaiwhakamahi mutunga.
- ;Te ātete o te whatungaKo ngā ngaohiko teitei ake me whai pūnaha tiaki matatau (hei tauira, ngā whati ara iahiko, ngā ārai ngaru).
;Ngā Pānga Ōhanga me te Taiao;
- ;Te whai huatanga o te utuE 4–5× te kaha ake o ngā raina UHV i ngā raina 500 kV, ā, ka whakaitihia ngā utu hanganga mō ia waeine.
- ;Te whakamahinga whenuaHe iti ake te wāhi e nohoia ana e ngā ara hiko UHV i ngā ara hiko maha e whakarara ana, e iti iho ana te ngaohiko.
- ;Te whakaiti waroMā te tuku pai e tautoko te whakamahinga o te pūngao hou.
;4. Ngā Rerekētanga o te Ao i roto i ngā Paerewa Ngaohiko;
Ahakoa he anga kei roto i ngā paerewa IEC, he rerekē ngā mahi ā-motu:
- ;Haina:
- UHV AC: 1,000 kV; DC: ±800 kV (hei tauira, raina Xiangjiaba-Shanghai).
- MV: 10 kV–35 kV.
- ;Ūropi:
- HV: 110 kV–220 kV; UHV: 380 kV (AC) me te ±500 kV (DC).
- ;Amerika ki te Raki:
- HV: 69 kV–230 kV; UHV: 500 kV (AC) me te ±800 kV (DC).
;5. Ngā Auahatanga o te Ao;
- ;Ngā whatunga atamaiTe whakaurunga o te IoT mō te aroturukitanga ngaohiko wā-tūturu.
- ;Ngā whatunga iti DCTe pikinga ake o te whakamahinga o te hiko DC i roto i ngā pūnaha MV/LV mō te whakaurunga o te hiko whakahou.
- ;Ngā rauemi matatauNgā kaiārahi hiko pāmahana-tiketike mō te tuku kore-ngaronga.
;Whakamutunga;
Mā te whakarōpūtanga ngaohiko ka pai te rere o te pūngao mai i te whakaputanga ki te kai. Ahakoa ko ngā ngaohiko iti me te reo te mea nui ki te urunga, ko ngā ngaohiko teitei me te tino teitei ka taea te whakawhanui me te whai hua. I te whanaketanga o ngā whatunga hiko ki te whakahaere mana motuhake me te pumau, ka haere tonu ngā paerewa ngaohiko ki te urutau, me te whakataurite i te pakari hangarau me te tiaki taiao.