+86 18068001229 Te Whakatau i te Kaha Utaina Mōrahi kW o tētahi Whakawhiti 1000kVA: Te Pānga o te Tauwehe Mana
Me pēhea te tatau i te whakatauranga kawenga kW o te whakawhiti hiko 1000kVA i runga i te tauwehenga mana
Me te momo tawhito1000kVA whakawhiti hikoI tēnei wā, e whakahaere ana i tētahi kawenga tata ki te 200kW, ka taea e tēnei whakawhiti hiko te whakatutuki i te pikinga o te tono mēnā kei te whakaaro tātou ki te tāpiri i tētahi kawenga hou tata ki te 600kW? Ko te kaupapa matua o tēnei pātai he ariā taketake: te whanaungatanga me te rerekētanga i waenga i te kVA me te kW.
Te whanaungatanga me te rerekētanga i waenga i te kVA me te kW
Ko te kVA (kilovolt-ampere) te waeine o te mana kitea, ko te kW (kilowatt) ia e tohu ana i te waeine o te mana hohe. Haunga te mana kitea me te mana hohe, kei reira anō te mana tauhohe, e inehia ana i roto i te kvar (kilovar).
He aha ngā rerekētanga i waenga i te mana hohe, te mana tauhohe, me te mana āhua?
Mana HoheKi te inehia ki ngā watts (W), e tohu ana i te pūngao tuturu e pau ana, i te mahi whai hua rānei e mahia ana e te ara iahiko (hei tauira, te whakamahana, te rama).
Mana TauhoheKi te inehia ki te volt-amperes tauhohe (VAR), ka tautokohia e ia ngā papa aukume i roto i ngā kawenga whakauru (hei tauira, ngā motuka) engari kāore e mahi tūturu. Hei tauira, mēnā he pūnga hiko, he koiri rānei kei roto i tētahi taputapu hiko, ka utua tonutia, ka tukuna atu hoki ēnei wāhanga i te wā e mahi ana te taputapu. Nā te mea kāore ngā pūnga/koiri e kai ana i te pūngao hiko i roto i tēnei tukanga utu/tuku, ka kiia te mana e pā ana ko te mana tauhohe.
Mana ĀhuaKi te inehia ki ngā volt-amperes (VA), koinei te huinga o te mana hohe me te mana tauhohe, e tohu ana i te mana katoa i roto i te ara iahiko. Me whakarato e te pūtake mana (he whakawhiti hiko, he whakaputa hiko rānei) ehara i te mea ko te mana hohe anake engari ko te mana tauhohe hoki ki ngā taputapu hiko. Nā te mea, ahakoa kāore ngā pūnga i roto i te taputapu e kai ana i te mana hohe, ko tā rātou utu me te tuku tonu me whakarite tonu te pūtake mana i tētahi wāhanga o tōna kaha hei tautoko i tēnei tukanga.
I muri i te whakamārama i ēnei ariā, ka taea e tātou te tirotiro i ō rāua whanaungatanga, e ārahi ana i a tātou ki tētahi atu ariā nui: te ira mana. Ko te nui o te mana hohe ka taea e te pūtake mana te tuku, e whakawhirinaki ana ki te ira mana.
He aha te tauwehe mana?
Ko te tauwehenga mana (cosΦ) te ōwehenga o te mana hohe (P) ki te mana āhua (S):
Hei tauira, ka taea e te whakawhiti hiko 1000kVA te tuku i te 600kW o te mana hohe ina 0.6 te tauwehe mana (cosφ), engari ka taea e ia te whakaputa i te 900kW o te mana hohe ina piki te tauwehe mana ki te 0.9.
Mena ko te utu hiko he $1 mō ia kilowatt-haora (kWh), ka taea e te whakawhiti hiko e mahi ana i te tauwehenga mana o te 0.6 te whakaputa i te $600/haora i roto i te moni whiwhi ōhanga. Ina piki ake te tauwehenga mana ki te 0.9, ka taea e te whakawhiti hiko kotahi te whakaputa i te ¥900/haora i roto i te moni whiwhi 45. Ahakoa e kitea ana ngā painga pūtea o te whakapai ake i te tauwehenga mana, ko ōna pānga hangarau whānui (hei tauira, te arotau i te pumau o te whatunga me te whakaiti i ngā ngaronga pūngao) ka horapa atu i tua atu i ēnei painga tonu.
E hia ngā kilowatt (kW) ka taea e te whakawhiti hiko 1000kVA te tautoko?
I runga i ngā mōhiotanga taketake kua whakapūmautia i runga ake nei, ka taea e tātou te aro atu ki te pātai matua o tēnei tuhinga me te mārama me te tika.
Ka inehia te kaha o te whakawhiti hiko i roto i te kVA (kilovolt-amperes), ko te kaha e pau ana i ngā taputapu hiko ka inehia i roto i te kW (kilowatts). Ko te rerekētanga matua ko te tatau i te mana hohe (kW) o tētahi taputapu me whakarea tōna mana kitea (kVA) ki te tauwehe mana (cosφ). Hei tauira, ka taea anake e te whakawhiti hiko 1000kVA te tuku i te putanga kawenga katoa o te 1000kW ina whakahaerehia i te tauwehe mana o te 1.0. Heoi, he mea tino kore e taea te whakatutuki i tēnei āhuatanga pai (PF = 1.0) i roto i ngā tono o te ao tūturu.
I te wāhanga hoahoa, ki te whakatinanahia e tātou te utunga tauwehe mana hei whakatutuki i te tauwehe mana o te 0.95, me tatau te putanga mana hohe o te whakawhiti hiko kia 1000×0.95=950kW. Pānui Hira: E whakahau ana ngā ratonga hiko kia ≥0.9 te tauwehe mana (PF) hei karo i ngā whiu; heoi, ki te nui ake i te ≥PF = 1.0 ka piki ake te ngaohiko o te pūnaha, ka whakararu hoki i te pumau o te whatunga hiko.
He1000kVA whakawhiti hikoi te tīmatanga ka tukuna he kawenga hiko 200kW. Whai muri i te tāpiri i tētahi kawenga hou 600kW, ka eke te katoa o te hiahia hiko hohe ki te 800kW, e noho tonu ana i roto i te rohe mahi haumaru kua tatauhia o te whakawhiti hiko.
Nō reira, he1000kVA whakawhiti hikoAhakoa te tāpiritanga o tētahi kawenga hiko hou ki te 600kW (800kW katoa), ka taea e te hiko e tuku ana i te kawenga hiko 200kW te mahi haumaru mō te wā roa, me te whakarite kia arotauhia te tauwehenga mana ki te taumata e hiahiatia ana.