E mōhio ana koe ki te rerekētanga i waenganui i Whakawhiti Koranu Āhua Koreme ngā whakawhiti hiko maitai silicon noa? Hei kaihanga whakawhiti hiko me te 15+ tau o te wheako, ka whakamārama a JZP i ngā rerekētanga i waenga i ēnei momo whakawhiti hiko e rua. Ehara i te mea he rerekētanga rauemi anake; he pakanga hangarau i waenga i te whai huatanga o te pūngao, te utu, me ngā au o te heke mai.

 

 

Koranu Āhua-kore VS. Whakawhiti Noa

 

Whakawhiti maitai silicon noa

Ko ngā whakawhiti hiko noa he matua i hangaia mai i ngā rau maitai silicon hurihuri-matao, he mea angiangi ki te witi, ā, ko ngā ngota o aua whakawhiti hiko he hanganga tioata ma, rite tonu.

Nā tēnei whakaritenga raupapa, he iti rawa te ātete aukume ina aukumetia i te ahunga hurihuri, ā, he tino pai te mahi. Heoi, he tioata tonu, ā, ka pau te kaha i te aukumetia, ka puta he "ngaronga hysteresis." Hei tāpiri, he matotoru motuhake ngā pepa maitai silicon, ā, ka puta he "aukume hurihuri" i roto i ngā papa aukume hurihuri, ka hua ake he "ngaronga aukume hurihuri," e mōhiotia whānuitia ana ko "ngaronga rino."

 

Whakawhiti Koranu Āhua Kore

Ko te uho o te whakawhiti koranu kore-āhua he mea hanga ki te rīpene kore-āhua, e mōhiotia ana ko te "karaihe whakarewa." He pōrearea, he koretake hoki tōna whakaritenga ngota. Ka hangaia tēnei hanganga mā te whakamatao tere i te rewa pāmahana tino-tiketike i te tere o te miriona nekehanga ia hekona, he tukanga ahurei. Ka whakaitihia e tēnei raruraru ngota tawhiti ngā ngaronga hysteresis; ko tōna matotoru tino angiangi me tōna ātete teitei ka whakaitihia ake ngā ngaronga iahiko hurihuri.

 

Whakataurite Mahi

Ahu Whakataurite

Whakawhiti Koranu Āhua Kore

 

Whakawhiti maitai silicon noa

 

Tātaritanga me te Whakamārama

 

Ngā Ngaronga Matua

 

Tino Iti

 

Teitei

 

Ko ngā mate kore-kawenga, i te toharite, he 60%-80% te iti iho i ngā whakawhiti maitai silicon S13/S14 rite tonu.

 

Auaha Kore-kawenga

 

Iti

 

Nui

 

Ka taea te whakaiti i te iahiko kore-kawenga mā te 40%-80% pea, ko te tikanga he iti ake te pānga o te mana tauhohe ki te whatunga hiko, ā, he iti ake hoki ngā mate raina.

 

Taumata Whai Hua Pūngao

 

Tino-Teitei

 

Teitei

 

Ka tutuki ngāwari i ngā whakawhiti hiko kore-āhua te paerewa whai huatanga pūngao ā-motu Akomanga I, e tohu ana i te tino whai huatanga pūngao ki te whakataurite ki ngā whakawhiti hiko maitai silicon (ko te Akomanga II, ko te Akomanga III rānei te nuinga).

 

Te Utu Hanga

 

Teitei

 

He iti noa iho

 

He utu nui, he mārō, he pakarukaru hoki te rīpene koranu kore-āhua, ā, he uaua ngā tukanga kutikuti me te whakamahana, ā, ko te mutunga iho he 20%-35% teitei ake ngā utu hanga i te maitai silicon o te kaha ōrite. Koinei tōna ngoikoretanga nui rawa atu.

 

 

Te Kaha Mīhini

 

Iti

 

Teitei

He mārō, he pakarukaru te rīpene koranu kore-āhua, ā, he iti te ātete ki te ru me te wiri. Me tino tupato i te wā e kawe ana, e tāuta ana, e ru ana hoki i te ara poto. He pakari ake te pepa maitai silicon, ā, he pai ake te ātete ki te pānga.

 

Te mātotoru rere aukume mahi

 

Iti (1.3-1.5T)

 

Teitei (1.6-1.8T)

 

He iti te kiato rerenga aukume kukū o ngā koranu kore-āhua, ko te tikanga he nui ake te horahanga whakawhiti matua e hiahiatia ana i te mana kotahi, ka hua ake pea tēnei i te pikinga paku o te rōrahi me te taumaha o te whakawhiti.

 

Haruru Whakahaere

 

Teitei Āhua

 

Iti

 

He nui ake te kitea o te pānga aukume (he panoni iti i te rahi o te rauemi ina aukumetia) o ngā koranu kore-āhua i tō ngā rau maitai silicon, ka hua ake he haruru nui ake (tata ki te 2-5 dB teitei ake) i te wā e whakamahia ana. Tērā pea me whakahaere motuhake i ngā wāhi e pāngia ana e te haruru.

 

Te Mahi Taiao

 

Tino pai

 

Pai

Ko te iti rawa o ngā mate kore-kawenga he nui ngā penapena pūngao puta noa i te huringa ora katoa (20-30 tau), he rite ki te whakaiti i ngā tukunga waro mā te maha tāne, mā te tekau tāne rānei.

Ngā whakawhiti hiko maitai silicon noa: He iti te haumitanga tuatahi, engari he nui ngā utu hiko whakahaere. Ka puta ō rātou mate kore-kawenga i ngā hāora 24 o te rā, ka pau tonu te hiko i te mea e hono ana te whakawhiti hiko ki te whatunga hiko.

 

Ngā whakawhiti koranu kore-āhua: He nui te haumitanga tuatahi, engari he tino iti ngā utu hiko whakahaere. Ahakoa he iti noa iho te penapena pūngao i te rā kotahi, ka taea e rātou te penapena nui rawa atu i roto i te huringa ora katoa (20-30 tau).

 

Mō ngā umanga he nui ngā Whakawhiti Tohatohame ngā āhuatanga kawenga iti (pērā i ngā kamupene whatunga hiko, ngā pokapū raraunga, me ngā matatini arumoni nui), he tino ātaahua ngā painga ōhanga o ngā whakawhiti hiko kore āhua.