He taputapu hiko hou te whakawhiti hiko momo-maroke i hangaia mō te tohatoha hiko haumaru, pono, me te whai hua i roto i ngā tono kanorau. Kāore i rite ki ngā whakawhiti hiko rumaki-hinu, ka whakamahia e ngā waeine momo-maroke he whakamarumaru totoka, he whakamarumaru hau rānei (hei tauira, te kapia epoxy, te kapia whakarewa, te hau SF6 rānei) hei utu mō te hinu kohuke, ka whakakore i ngā mōrearea ahi me te poke o te taiao. He pai mō ngā whakaurunga o roto, ngā taiao tāone, me ngā wāhi tairongo, ka whakakotahi ēnei whakawhiti hiko i te pumau, te iti o te tiaki, me te mahi teitei.

    Ngā Āhuatanga Matua me ngā Painga

    Hoahoa Ārai Ahi me te Hoahoa Taiao
    Kāore he hinu mura, ka tutuki i ngā whakawhiti hiko momo-maroke ngā paerewa haumaru ahi tino pakari (IEC 61558) ā, he pai hoki mō ngā hōhipera, ngā pokapū raraunga, me ngā whare noho. Mā ngā rauemi hangarua me te kore turuturu hinu ka tutuki ai ngā whakaritenga taiao.
    'Teitei o te Whai Hua me te Penapena Pūngao
    Mā ngā rauemi matua matatau (te koranu kore-āhua, te maitai silicon rānei) me ngā hoahoa takai kua arotauhia ka whakaitihia te ngaronga pūngao tae atu ki te 30%, ka tutuki ai ngā taumata whai hua ≥98% (kua whakamanahia e IEC 61378). He pai mō te mahi tonu me te iti o te whakaputa wera.
    'He iti te tiaki me te roa o te ora
    Ka ātete ngā pūnaha whakamarumaru totoka ki te makuku, te puehu, me ngā poke matū, ka whakaiti i ngā hiahia tiaki. Ka ātete te hanganga pakari ki ngā āhuatanga uaua, ka roa ake te ora o te mahi i roto i ngā taiao ahumahi, takutai rānei.
    'Kiato & Penapena Wāhi
    Mā ngā hoahoa pūrua me ngā tapuwae kiato ka māmā ake te tāutanga ki ngā teihana hiko o te tāone, ki ngā whare arumoni, ki ngā wāhi pūngao whakahou rānei. Kei te wātea mai i ngā ngaohiko mai i te 380V ki te 36kV me ngā kaha tae atu ki te 5 MVA.
    'Aroturuki Atamai me te Haumaru
    Ka aroturukihia e ngā pūoko IoT kōwhiringa te pāmahana, te ngaohiko, me te kawenga i te wā tūturu, ka taea ai te tiaki matapae. Ka āraihia e ngā pūnaha tiaki kua hangaia (hei tauira, ngā whakawhiti wera, ngā whakaoho Buchholz) ngā hapa me te whakarite kia haumaru te mahi.
    Whakawhiti Hinuhinu Cooper Rukuhia Auautanga Teitei 10001Whakawhiti Hinuhinu Cooper Rukuhia Auautanga Teitei 10002Whakawhiti Hinuhinu Rukuhia Cooper Auautanga Teitei 10003
    Ngā Whakawhiti Momo-Maroke-Teitei-Pai
    • Ngā Whakawhiti Momo Maroke-Teitei-Te-Pai (1)
    • Ngā Whakawhiti Momo Maroke-Teitei-Pai (2)
    • Ngā Whakawhiti Momo Maroke-Teitei-Pai (3)
    • Ngā Whakawhiti Momo Maroke-Teitei-Teitei (4)
    • Ngā Whakawhiti Momo Maroke-Teitei-Pai (5)
    Whakawhitinga Ruku Hinu Cooper01

    Ngā tono

    Hanganga Tāone: Te tohatoha hiko haumaru i ngā wāhi kiato, i ngā toa hokohoko, me ngā pūnaha tereina raro whenua.
    Whakamahinga Ahumahi: He pumau te tuku rauemi mō ngā whare hanga, ngā mahi keri, me ngā ahumahi matū.
    'Pūngao Whakahou: Te whakaurunga ki ngā pāmu pūngao rā/hau mō te hononga whatunga whai hua.
    'Ngā Whare Pakihi: Ngā pūnaha HVAC, ngā ararewa, me ngā whatunga rama.

    Ngā Whakatakotoranga Hangarau

    Awhe Ngaohiko: 380V ki te 36kV (ngaohiko waenga).
    'Te kaha: 50 kVA ki te 5,000 kVA.
    'Ngā Momo Whakamatao: Te Hau Taiao (AN) te Hau Āwhina rānei (AF).
    'Akomanga Whakamarumaru: Akomanga-H (180°C) mō te ātete wera nui.
    'Auautanga: 50Hz/60Hz.

    Te Whakapūmau Kounga

    Kei roto i ngā whakamātautau pakari ko te ngaohiko hiko, te ngaronga kawenga, me te whakatauira pikinga pāmahana.
    Kua whakamanahia e IEC, IEEE, ISO 9001 (kounga), me te ISO 14001 (taiao).

    He aha mātou i whiriwhiri ai?

    30+ Tau o te Tohungatanga: He hoahoa kua whakamātauhia mō ngā pāmahana tino kino, te haumākū, me ngā rohe rū whenua.
    'Tautoko Ao: Ngā tīma hangarau ā-rohe me te āwhina hangarau 24/7.
    'Ngā Otinga Whai Hua: He hoahoa tauine me ngā kōwhiringa putea ngāwari.

    Ngā Otinga Ritenga

    Ngā Tauira Ātete-Ahi me te Ārai-Pahūtanga: Mō ngā whakaurunga hinu/hau, mō ngā wāhi morearea rānei.
    'Ngā Hoahoa Ā-Taiao: He iti te haruru (
    'Ngā Pūnaha Ranu: Kua honoa ki te rokiroki pūngao mō ngā tono whatunga atamai.
    Whakawhitinga Ruku Hinu Cooper02Whakawhitinga Ruku Hinu Cooper03Whakawhitinga Ruku Hinu Cooper04Whakawhitinga Ruku Hinu Cooper05

    Ngā painga o te hua

    1. Ngā Rauemi Matua me te Hoahoa Matapihi​
    Ngā Rauemi Matua
    Ngā Matua Koranu Kore-āhua:
    He tino iti te ngaronga o te rino (70–80% te iti iho i te maitai silicon tuku iho), ka whakaiti i te moumou pūngao me ngā utu whakahaere.
    Ka whakaitihia te haruru me te wiri e te urunga nui me te tata ki te kore o te aukati aukume, he mea tino pai mō ngā rohe noho me ngā rohe arumoni.
    ​Te maitai hiko hurihuri-makariri (CRGO):
    Ka whakaitihia ngā ngaronga o te iahiko hurihuri e ngā whakapiringa tapahi-reera, e ngā whakapiringa takahanga-taahiraa rānei, kia eke ai ki ngā taumata whai huatanga tae atu ki te 98% (ngā paerewa IEC 60076).
    Ka whakarei ake te whakatakotoranga o te witi kua arotauhia i te kiato rerenga aukume mō ngā tono ngaohiko-tiketike (tae atu ki te 33kV).
    Hoahoa Whakakorikori
    Ngā takai konumohe me te whakakī kapia:
    Ka whakaitihia te rere o te turuturu me ngā kaha o te ara iahiko poto e ngā takai parahi, te konumohe rānei. Ka whakarei ake te whakakī kapia epoxy i te kaha miihini me te kawe wera.
    Ka whakaitihia e ngā paparanga honohono te ahotea ngaohiko i waenga i ngā hurihanga, ka whakapai ake i te manawanui o te ara iahiko poto (tae atu ki te 50 kA ngā hapa kore taurite).
    Ngā takai waea Litz paparua:
    Ka whakaitihia e te waea Litz maha-aho ngā pānga ki te kiri me te tata, ka whakaitihia te ātete AC i roto i ngā tono auau teitei (hei tauira, ngā kaitahuri HVDC).
    ​Te Whakakī Pēhanga Korehau (VPI):
    Ka whakakiia ngā koiri ki ngā kapia epoxy, polyester rānei e pāmahana teitei ana, kia mau ai te ātete ki te makuku me te kaha dielectric tae atu ki te 200 kV BIL.
    ;2. Ngā Pūnaha Whakamarumaru​
    Te Makahanga Resin Epoxy:
    Mā te whakamarumaru totoka me ngā kapia epoxy Akomanga H ka ātete ki te ahi (kua whakamanahia e UL94 V-0) ā, ka tu atu i te huringa wera (−40°C ki te +155°C).
    He ātete pai rawa atu ki te tukunga wāhanga, he mea tino pai mō ngā taiao poke, makuku rānei.
    ​Te Hanganga Pepa Nomex:
    Ka tukuna e te whakamarumaru muka aramid he pumau wera teitei (tae atu ki te 220°C) me te kaha dielectric, me ngā āhuatanga ātete mura.
    ​Te Āraitanga Whakarei-Nano:
    Ka whakapai ake ngā hiato epoxy whakakīia ana ki te silica i te roanga o te wā tukunga wāhanga mā te 40%, ka roa ake te roa o te wā ratonga i roto i ngā āhuatanga uaua.
    ;3. Whakahaere Wera
    ​Whakamatao Hau-Taiao (AN):
    Whakamatao kore mahi mā roto i ngā pūwhakamahana whai tara, mā roto rānei i ngā totohu wera hei mahi tonu i ngā kawenga kua whakatauria (hei tauira, ngā waeine 500kVA–1.5MVA).
    Whakamatao Hau Āwhina (AF):
    Ka whakarei ake ngā pā hau e whakahaeretia ana te pāmahana i te mararatanga o te wera, ka taea ai te 120–150% te kaha uta i ngā wā ohorere.
    Aroturuki Wera Atamai:
    Ka whakaohohia ngā whakaoho, ngā whakarerekētanga whakamatao rānei e ngā pūoko pāmahana kua whakauruhia me ngā pūnaha IoT hei ārai i te wera nui me te pakaru o te whakamarumaru.
    ;4. Te Hoahoa Hanganga me te Tiakitanga
    Hoahoa Āhuahira me te Hoahoa Kiato
    Ngā Kāinga Hermetic:
    Ka ārai ngā ārai IP66/IP67 me ngā gasket EPDM i te puehu, te wai, me te urunga mai o ngā kiore, he mea tika mō ngā taiao o waho, o ngā taiao ahumahi rānei.
    Ngā paninga ārai-waikura:
    Ka ātete ngā ārai maitai piauau wera-tuku ki te rino, ki te konumohe rānei, he paninga polyurethane/paura rānei, i te pirau UV me te pānga ki te tote o te takutai.
    Ngā Rauemi Ātete-Ahi:
    E tutuki ana i ngā pūnaha whakamarumaru kore-mura me ngā pūnaha kapia tineia-ake ngā paerewa haumaru ahi IEC 60335.
    Ngā Āhuatanga Haumaru
    Ngā Pūnaha Whakaiti Pēhanga:
    Ka ārai ngā pūhaumātao pēhanga aunoa i ngā pakaru pahūtanga i ngā hapa o roto.
    Te Parenga Ngaru:
    Ka pehia e ngā ārai waikura whakarewa whakauru (MOA) ngā whakawhiti i puta mai i te uira (≥2.5 kA ngā iri).
    Te Ārai i te Whakatakotoranga me te Ringihia:
    Mā ngā pūnaha whenua whakapakari me ngā hoahoa hiri ka kore e turuturu te hinu, ka kore ai e poke te taiao.
    ;5. Mahi Matatau
    Ngā Pūnaha Aroturuki Āhua (CMS):
    Ka aro turukihia e ngā pūoko tāmau te pāmahana o te takai, te tukunga wāhanga, me ngā taumata kawenga, ka taea ai te tiaki matapae mā ngā tūāpapa SCADA, IoT rānei.
    ​Whakaurunga Mātiti Atamai:
    Ka tautokohia e te whakawhitiwhiti kōrero ā-IoT te aroturuki mamao, te taurite kawenga, me ngā urupare whatunga whakaora-ake.
    Ngā Auahatanga Taiao-hoa:
    Ko ngā kapia ārai mate koiora me ngā wāhanga pūmua hangarua e hangai ana ki ngā whāinga oranga tonutanga (hei tauira, te hanganga ture mō te RoHS me te REACH).
    Ngā Whakamahinga Matua me ngā Auahatanga o te Ao
    Te Tohatoha ki te Tāone me te Arumoni:
    Ngā wāhi hiko kiato nui (500kVA–2 MVA), ngā pokapū raraunga, me ngā teihana utu EV.
    Pūngao Ahumahi me te Pūngao Whakahou:
    He pai mō ngā teihana hiko pūngao rā/pāmu hau, ngā papa keri maina, me ngā wāhi morearea (Rohe 2/22).
    Ngā Whakatairanga ā-Mārama:
    Ngā Whakawhiti Āhua-Toka (SST): Whakahohe i te huringa DC-DC me te ngāwari o te whatunga mō ngā pūnaha pūngao pokapū.
    Ngā Nanocomposites Whakamatao-Anō: Ka tohatoha motuhake ngā rauemi matatau i te wera i raro i ngā āhuatanga hapa.
    Whakarāpopototanga
    He tino pai ngā Whakawhiti Momo-Maroke nā roto i ngā matua kore-mate iti, te ātete pakari ki te whakamarumaru, me te whakahaere wera atamai. Nā te haumaru ahi, te whakahaere kore tiaki, me ngā hoahoa hoa-taiao e tino hiahiatia ai mō ngā whatunga tāone me ngā whatunga ahumahi hou, ā, ko ngā auahatanga pēnei i te hangarau totoka me te whakaurunga IoT e akiaki ana i te mōhiotanga me te pumau o te whatunga.
    Whakawhitinga Ruku Hinu Cooper06Whakawhitinga Ruku Hinu Cooper07Whakawhitinga Ruku Hinu Cooper08Whakawhitinga Ruku Hinu Cooper09

    Uiui Inaianei!

    Mō ngā pātai e pā ana ki ā mātou hua, ki te rārangi utu rānei, waiho mai tō īmēra ki a mātou, ā, ka whakapā atu mātou i roto i ngā haora 24.

    Leave Your Message