Whakawhitihiko Whakamau Papa-3-Wāhanga 225 kVA 34.5kV

Ngā Whakatauranga Ngaohiko Matua: 34.5kV
Ngā Whakatauranga Ngaohiko Tuarua: 600/347V
Momo Hononga: Dyn1
Momo: Kua mau te papa
Ngā Paerewa: CSA C227.4
Taupānga: Ngā pūnaha tohatoha ahumahi
Whakatauranga Mana: 225kVA
Tiwhikete: CUL
Tikanga Whakamatao: NOHO ATAAHUA, Ā, AROHA MAI

    Whakaahuatanga Hua

    E whakahīhī ana a JZP Transformer ki te whakauru i te transformer 225 kVA 34.5kV 3-wāhanga e mau ana ki te papa hiko, i hangaia mō ngā pūnaha tohatoha ahumahi. He mea hanga ki ngā paerewa teitei, ā, ka whakarite kia pumau te tuku hiko mō ngā momo tono ahumahi.
    tiwhikete01
    tiwhikete02
    tiwhikete03
    tiwhikete04
    tiwhikete05
    tiwhikete06
    tiwhikete07
    tiwhikete08
    tiwhikete09
    01020304050607
    TE WHAKAPĀNUI WHAKAPĀNUI E TORU ANA TE PAPA

    Ngā Whakatakotoranga Hangarau mō te Whakawhiti 225 kVA 34.5kV

    MANA WHAKATAURANGA 225 kVA
    WHAKATAURANGA NGAOHIO TUATAHI 34500DELTA
    NGAOHIO TUARUA 600GrdY/347
    AUAUTANGA 60Hz
    RŌPŪ WEKTOR Dyn1
    RAUEMI WHAKAWHITI Konumohe
    TE NGAROTANGA O TE KAUPAPA ≤2350W
    KĀORE HE NGAROTANGA UTA ≤650W
    TE NGAOHIO ĀRAITANGA 5.75%
    TEITEI ≤1,500m
    TAE ANSI 70 Hina mārama
    TAUMAHA HINU WHAKAMĀTAO 1,040 rita
    TAUMAHA KATOA 2,300 kirokaramu
     

    225 kVA 34.5kV Whakawhiti Apatoko

    TE WHAKAPUTANGA I TE RINGA HUI ELSP
    TŪAHA WHAKAPĀ HUI PĀYONETI
    TAUPAPA TŪ WAKA PANUITANGA TAP
    UHI TAKE Ine Taumata Hinu
    LV BUSHING (4-PŪ) RĀWA WHAKAMĀTAU PĒHANGA
    PŪRERE WHAKAMĀMĀ PĒHANGA Ine Pēhanga Korehau
    PAE PARAHI HV WHENUA PORAKA TAURANGA
    TOHU PĀMAHANA KĀKAHU O TE TŪAHA
    Puna Pūwero HV (35kV) WHERO WHENUA PARAHI
    KAKAU PAE PARAHI WHAKAWHĀNUI INGOA
    RUA NGĀ TŪRANGA WHAKAMĀTAU UTA NGĀ PAPA RINO WHENUA
    1"'RĀWAI WHAKAMĀTAU ME TE TAURA 3/8" Matapihi IR
    HONONGA PĒHI TĀTARI RĀWAI WHAKAKĪ 1" O RUNGA Pouaka Whakamutunga

    Ngā Āhuatanga Matua
    Matapihi IR (Matapihi Whero)
    Kei ia whakawhiti hiko he Matapihi IR i ngā wāhanga ngaohiko-tiketike me ngā wāhanga ngaohiko-iti, e āhei ai ngā kaiwhakahaere ki te mahi i ngā matawai wera infrared me te kore e whakatuwhera i ngā tatau. Mā tēnei hoahoa ka whakarite kia haumaru, kia whai hua hoki ngā tirotiro, kia taea ai te kite wawe i ngā wāhi wera pea, i ngā take werawera rānei. Mā te tautuhi i ngā mōrearea pēnei i te taumaha rawa, ngā hononga koretake, te whakapā ngoikore rānei, ka whakarei ake te Matapihi IR i te pumau me te haumaru o te mahi a te whakawhiti hiko.

    Ngā Pūrere Tiaki Matatau
    Kei te whakawhiti hiko 225 kVA te whānuitanga o ngā tikanga tiaki matatau hei whakarite i te haumaru mahi me te roa o te ora mahi, tae atu ki:

    Ine Pēhanga Korehau: Kei roto ko ngā hononga whakaoho e rua mō te aroturuki pēhanga i te wā tūturu, hei whakatūpato wawe i ngā raruraru pea.

    Pūrere Whakamamae Pēhanga: He mea hono ki ngā hononga, ka whakaoho i tētahi tohu hiko ina kitea he pēhanga rerekē, hei whakamōhio i ngā kaiwhakahaere kia mahi i ngā mahi e tika ana.

    Tohu Taumata Hinu: E rua ngā whakapā whakaoho hei whakatūpato i te pūnaha aroturuki ina he rerekē te taumata hinu, e āhei ai ngā kaiwhakahaere ki te whakarerekē tere i te taumata hinu me te pupuri i te mahi haumaru.

    Tohu Pāmahana Hinu: Kei roto ko ngā hononga whakaoho e rua—kotahi mō ngā tohu whakatūpato, ko tētahi mō ngā tohu whati. Mēnā ka neke ake te pāmahana hinu i te 70°C, ka tukuna he whakatūpato e te pūnaha; ki te neke ake i te 105°C, ka whati aunoa te whakawhiti hiko, ā, ka tukuna he tohu e te pūnaha aroturuki hei tohu i te hapa.

    Hoahoa Ataahua-Kaiwhakamahi me te Aroturukitanga o Waho
    Ngā Ine Whakamau ki Waho me te Takirere Wai me te Tauira: Ka taea e ngā kaiwhakahaere te whakamātautau i te hinu whakamahana me te tirotiro i ngā ine me te kore e pā ki ngā pū hiko teitei me te iti, ka whakarei ake i te haumaru, te whai hua, me te tutuki i ngā whakaritenga.

    Parepare Tiaki Pūrere Whakaiti Pēhanga: Ka ārai te parepare tiaki i ngā kino o waho, te whakahohenga tūpono, me te pokanoa mai i ngā āhuatanga taiao, kia tika ai te mahi a te pūrere whakaiti pēhanga, kia whakaitihia ai hoki te mōrearea o te turuturu hau. Ka ārai hoki i ngā poke kei uru ki te whakawhiti hiko, kia mau tonu ai te ma me te pumau mō te wā roa.
    Ngā Āhuatanga Matua

    Te Whai Hua me te Auahatanga
    Kua hangaia te whakawhiti hiko 225 kVA mai i te JZP Transformer me te aro nui ki te pono me te haumaru mō te wā roa. Mā te whakamahi i ngā matapihi infrared, ngā pūnaha aroturuki atamai, me ngā mana whakahaere o waho e ngāwari ana ki te whakamahi, ehara i te mea ka whakapai ake te whakawhiti i te whai huatanga o te mahi engari ka whakarei ake hoki i te haumaru o ngā mahi tiaki. Mā ēnei āhuatanga ka āwhina i ngā kaiwhakahaere ki te kite me te whakatika wawe i ngā raruraru pea, me te whakaiti i te wā mutu me te whakarite kia haere tonu te whakaputa.
    Te Whai Hua me te Auahatanga

    Ngā tono mō te whakawhiti hiko 225 kVA
    Ngā pūnaha tohatoha hiko ahumahi
    Pūnaha hiko arumoni me te whare noho
    Ngā teihana pūngao whakahou me te hurihanga hiko
    Ngā pokapū raraunga me ngā hanganga matua
    Ngā kawenga hiko e hiahiatia ana
    Whakawhiti JZP—Te Whakarite i te Mana Pono mō ō Hiahia
    E whakapau kaha ana a JZP Transformer ki te whakarato i ngā otinga hiko kounga teitei ki ngā kiritaki o te ao katoa. Mā te hangarau matatau me te whakahaere kounga pakari, ka whakarite mātou i te pumau me te pono o te tuku hiko mō ngā kaupapa ahumahi me ngā kaupapa arumoni. Ahakoa he tāutanga taputapu, he tiaki, he hoahoa ritenga rānei, ka whakarato mātou i ngā ratonga ngaio me te tautoko.
    Ngā tono mō te whakawhiti hiko 225 kVA

    Uiui Inaianei!

    Mō ngā pātai e pā ana ki ā mātou hua, ki te rārangi utu rānei, waiho mai tō īmēra ki a mātou, ā, ka whakapā atu mātou i roto i ngā haora 24.