Leave Your Message

Whakawhitiwhiti Whakamau Papa Wāhanga Toru 2500kVA

Ngā Whakatauranga Ngaohiko Matua: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, ētahi atu rānei
Ngā Whakatauranga Ngaohiko Tuarua: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v me ētahi atu rānei
AWHINA TAP HV: ±2×2.5% me ētahi atu rānei
Momo Hononga: Dyn11/YNyn0 me ētahi atu rānei
Momo: Whāngai porowhita/Whāngai pūtoro
I: 30/150 kV
Ngā Paerewa: IEEE, CSA, DOE
Taupānga: BESS, Keritanga Crypto, Ahumahi, Pūngao Hau me te Rā, Utu EV
 Whakatauranga Mana: 2500 kVA, 2550 kVA, 2.5 MVA
Tiwhikete: UL, CUL, CSA, SGS

    Whakaahuatanga Hua

    He kaihanga ngaio a JZP Transformer mō ngā whakawhiti hiko me ngā rārangi UL me ngā tiwhikete mō ngā taumata ngaohiko tae atu ki te 44kV, e tuku ana i te whānuitanga o ngā whakawhiti hiko kua whakamanahia e te UL. Ia tau, ka kaweake mātou i ngā mano o ēnei whakawhiti hiko ki te United States me Canada. He mātau ki ngā paerewa IEEE/ANSI, CSA, DOE, NEMA, me ētahi atu, ka whakarite tā mātou tīma kia tutuki ngā whakaritenga ture rerekē. Haunga te tiwhikete UL, kei a mātou anō ngā tiwhikete CSA, MF, CESI, me ngā pūrongo whakamātautau SGS tuatoru. Me te wheako nui ki te kaupapa, e mārama ana mātou he whakaritenga ahurei tō ia kaupapa. Koia mātou e tuku ana i ngā whakawhiti hiko ka taea te whakarite, e āhei ai te whakarerekē i te ngaohiko, te kaha, te tikanga hononga, me te hoahoa motuhake kia tino rite ki ō hiahia. Ka taea te whakarite i te whakawhiti hiko 2500 kVA kua mau ki te papa kia rite ki ō hiahia kaupapa. Whakapā atu ki a Daelim Transformer i tēnei rā kia whiwhi ai i te pepa tawhā, ngā tuhi, me te whakatau utu mō te whakawhiti hiko 2500 kVA kua mau ki te papa.
    tiwhikete01
    tiwhikete02
    tiwhikete03
    tiwhikete04
    tiwhikete05
    tiwhikete06
    tiwhikete07
    tiwhikete08
    tiwhikete09
    01020304050607

    Ngā Whakatakotoranga o te Whakawhiti 2500 kVA (2.5 MVA)

    Wāhanga Wāhanga-toru Paerewa Paerewa ANSI/IEEE C57 me te Paerewa DOE 2016
    Whakatauranga mana 2000kVA (2.5MVA) Whirihoranga Whāngai mua/porowhita mate
    Te Whakamaunga Maunga Papa Auautanga 60Hz
    Ngaohiko HV 13200/6720V Kaiwhakawhiti tap 5-tūranga
    Ngaohiko LV 600/347V Te kaha o te wai 1600L
    HE AHA TE MOTUKA 95 kV Taumaha katoa 7000kG
    Waka LV 30 kV Kāore he ngaronga kawenga 2500W
    Rōpū Waehere I roto i te 0 I te ngaronga kawenga 15000W
    Tikanga whakamatao NOHO ATAAHUA, Ā, AROHA MAI Āraitanga 5.75%
    Rauemi Whakakorikori Konumohe Tae Peita Munsell matomato
    Wai Whakamaroke Hinu huawhenua pirau-koiora Te pikinga o te pāmahana i te 65℃ 2500 kVA
    Puka matua E toru ngā wāhanga, e rima ngā pou Hau Whakahau (Ngā Pā) Kāore

    Ngā Āhuatanga o te Whakawhiti 2500 kVA
    Ngā Āhuatanga o te Whakawhiti 2500 kVA
    Ko te mana o te whakawhiti hiko ZGSL-H-2500/13.2-0.6 he 2500 kVA (2.5 MVA). Ko te ngaohiko tuatahi o te whakawhiti hiko 2500 kVA e mau ana ki te papa he 13.2/7.62 kV me te hononga Wye, te whenua H0 ngaohiko teitei, me te ngaohiko tuarua 600Y/347V Wye me te whenua H0 ngaohiko iti.

    He maha ngā whakamahinga o te whakawhiti hiko ZGSL-H-2500/13.2-0.6 2500 kVA, ā, he pai mō te tāutanga o roto, o waho hoki. He wai whakamātao hinu huawhenua pirau ēnei whakawhiti hiko, ā, ka mau tonu te pikinga pāmahana 65°C. E toru ngā fiusi ELSP me ngā fiusi bay-o-net e toru hei tiaki, me ngā pūkaha ngaohiko-tiketike e toru, ngā ārai tuke e toru (HV), me ngā pūkaha ngaohiko-iti e whā, ia pūkaha he 6 ngā kōhao. Ka whakapakaritia te tūranga tāutanga pito ngaohiko-tiketike ki te pereti Padmount. Hei tāpiri, kei te whakawhiti hiko 2500 kVA e mau ana ki te papa he pana whati-uta e whā ngā tūranga me te whakawhiti tap e rima ngā tūranga i te taha ngaohiko-tiketike.

    ZGSL-H-2500/13.2-0.6
    Ko te ZGSL-H-2500/13.2-0.6 he whakawhiti hiko e toru-wāhanga ana, 2500 kVA te kaha, he tohu UL tōna. E piri ana te whakawhiti hiko 2500 kVA ki te paerewa IEEE C57.12.34, ā, e tutuki ana hoki i ngā ture DOE. He mea hanga ki ngā ara iahiko konumohe, ā, kua whirihorahia hei whakawhiti momo whāngai-porowhita mō ngā pūnaha mate-mua. Ko te tikanga whakamatao e whakamahia ana ko te KNAN.

    ZGS-Z-2500(3050)/44/0.6
    Ko te ZGS-Z-2500(3050)/44/0.6 he whakawhiti hiko motuhake 2500 kVA e mau ana ki te papa ora, i hangaia hei whakatutuki i ngā hiahia ahurei o ngā kiritaki o Kanata nā Daelim Transformer. E tutuki ana tēnei whakawhiti hiko 2500 kVA e mau ana ki te papa i ngā paerewa CSA C227.4 me CAN/CSA 802.1. He ngaohiko teitei o te 44 kV i te whirihoranga Delta me te ngaohiko iti o te 600GrdY/347V.

    Kei te whakawhiti hiko te hinu RAPO pirau hei wai whakamahana, ā, kua hangaia mō te pikinga pāmahana o te 55°C, o te 75°C rānei. Ko tōna whakatauranga kVA he 2500 kVA (2.5 MVA) i te pikinga pāmahana o te 55°C me te 3050 kVA i te pikinga pāmahana o te 75°C.

    ZGS-Z-2500(3050)/44/0.6
    Ko te mea e wehewehe ai tēnei whakawhiti hiko 2500 kVA ko tōna ngaohiko iti kua hangaia kia puta mai i te taha. Hei tāpiri, ko ngā ine, te whakawhiti tap, te pereti ingoa, te takirere whakamāmā pēhanga, me te takirere whakakī o runga kei waho o te kāpata o mua. He hononga kei roto i ēnei ine, ā, kua honoa ki roto i tētahi pouaka whakahaere o waho NEMA 4. Kei runga ake o te kāpata o mua he ine pēhanga korehau. Ko te pūngao ngaohiko teitei he pūngao whakauru porcelain me ngā kōhao e whā, ā, e toru ngā ārai uira kei te taha HV, ia pūngao he taupoki whakamarumaru hei tiaki i ngā taura MV. Hei tāpiri, kua tāutahia ngā whakamahana ārai-hauota ki roto i te kāpata ngaohiko teitei o mua mō te mahi tino pai.
    2

    Whakawhiti hiko 2.5 MVA 3 PH
    Ko te ZGSL-Z-2500/44/4.16(2.4) he whakawhiti hiko motuhake 2.5 MVA e toru-wāhanga ana te pūngao radial e mau ana ki te papa hiko. Ko tōna whakatauranga ngaohiko tuatahi ko 44,000 Delta V, ko te ngaohiko tuarua ko 4160Y/2400 V. Kua whirihorahia te whakawhiti hiko ki te rōpū hononga ngaohiko teitei me te iti DYn1, ā, e tutuki ana i te paerewa CSA C227.4. E whakamanamana ana ki te whai huatanga pūngao whakamiharo o te 99.37%, e rite ana ki te paerewa CAN/CSA-802.3. Ko te aukati o te whakawhiti hiko i te 85°C ko 5.75%, ā, e whitu ngā taumata whakahaere ngaohiko e tukuna ana mō te taha ngaohiko teitei. Me te kaha hinu whakamarumaru o te 2000L me te taumaha o te 7500 kg, he taputapu nui tēnei.
    2

    Whakawhiti 2.5 MVA
    He mea nui, he hoahoa tōna e whakapūmau ana i te taha whakairi o ngā wāhanga ngaohiko teitei me ngā wāhanga ngaohiko iti, ā, ko te wāhanga ngaohiko teitei he rūma pito hau kua whakanohoia pai ki tōna turanga. Ko te whakaurunga o ngā takirere taputapu me ngā taputapu kua whakanohoia ki te pakitara o waho o te tāke wahie ka whakarei ake i te urunga atu me te whakarite kia pai ake te whakamahi, hei tauira mō te hoahoa i hangaia paitia o te whakawhiti hiko.
    2550 kVA Whakawhitinga Whakamau Papa

    2550 kVA Whakawhitinga Whakamau Papa
    Ko te ZGSL-H-2550/34.5/0.415 he whakawhiti hiko pakari e toru-wāhanga, he momo porowhita-whakairoiro, he mana whakamiharo o te 2550 kVA. He tino pai me te kaha ngaohiko teitei o te 34.5 kV me te tuku putanga ngaohiko iti o te 415Grd/240V. He mea whakamiharo, ko ōna takai ngaohiko teitei (HV) me te ngaohiko iti (LV) he mea hanga tino pai mai i te konumohe. Ko tēnei whakawhiti hiko he 99.4% te whakatauranga whai huatanga, ā, e tino tutuki ana ki te paerewa IEEE Std C57.12.34. Hei tāpiri, ko te whakaurunga o te pana wehenga kawenga e whā-tūranga ka whakarei ake i te mahi me ngā mahi haumaru.
    Whakawhiti 2550 kVA

    Whakawhiti 2550 kVA
    Ka whakamahia e te whakawhiti hiko 2550 kVA te pūnaha whakamatao ONAN/ONAF, nō reira, kei roto he huinga pā. Ina whakamahia i roto i te tikanga whakamatao ONAN, ko te whakatauranga mana o te whakawhiti hiko he 2550 kVA. Heoi, ka taea e te tikanga whakamatao ONAF te whakahaere i te whakatauranga mana teitei ake o te 3300 kVA. He mea nui, kei te whakawhiti hiko he ine pāmahana hinu me ngā hononga whakaoho, ā, kua honoa ki tētahi kāpata whakahaere rino kowiri tira 304 iti. Mā tēnei whirihoranga ka taea te aroturuki mamao i te tūnga mahi o te whakawhiti hiko.

    E whā ngā waeine o te raupapa ZGSL-H-2550/34.5/0.415, he mea hanga motuhake mā ngā kiritaki o Amerika, ā, kua rārangihia ki te rārangi UL kia tutuki ai ngā paerewa haumaru me te kounga pakari.

    ZGSL-H-2550/12.47/0.415
    Ko te raupapa ZGSL-H-2550/12.47/0.415 he puranga o ngā whakawhiti hiko 2550 kVA i hangaia e JZP Transformer mā te kiritaki o Amerika. He momo papa-mau ēnei whakawhiti hiko, ā, he whirihoranga whāngai porowhita kei roto. Ko ngā whakatakotoranga matua o ēnei whakawhiti hiko ko te pana whati-uta e whā ngā tūranga, he whakawhiti tap e rima ngā tūranga, he ine me te āhuatanga kore-pā, e toru ngā fiusi bay-o-net, me ngā fiusi whakawhāiti-auau e rua.
    12

    12.47 kV 2550 kVA Whakawhiti
    I te taha iti-ngaohiko, kei te rarangi he whāriki hei tautoko i te pito. Ko te wai whakamahana e whakamahia ana ko te hinu kohuke ASTM II, me te kaha o te 440 karani. Kua hangaia te tāke kia tu atu i te pēhanga tāke pai mōrahi o te 10 PSI me te pēhanga tāke kino o te 8 PSI. Ka puritia te taumata wai i te 10.0 inihi mai i te tihi o te kōhao ringaringa i te 25℃, me ngā huringa taumata o te 0.4 inihi ia 10℃. Kua hangaia te tāke mō te whakakī korehau 7 PSI, ā, kua whakatauria mō te 2550 kVA ina whakakahangia i te 11,847 volts me te whakawhiti tap i te tūranga 124,700-volt mō te ngaohiko tuarua o te 415Y/240. Kāore he taumata PCB e kitea ana i roto i ēnei whakawhiti hiko (iti iho i te 2 ppm) i te wā i hangaia ai, kia mau ai te haumaru me te tutuki i ngā whakaritenga taiao.
    13

    13.2 kV 2550 kVA Whakawhiti
    He taputapu whakawhiti hiko motuhake te 2550 kVA, he mea whai tohu UL, e whakamana ana i te tutuki i ngā paerewa haumaru me te kounga pakari. Ko te rōpū hononga mō tēnei taputapu whakawhiti hiko ko Dy1·Dd0, e rua ngā tikanga hononga motuhake mō te ngaohiko iti:

    Mō te hononga Wye 4160V, kei roto i ngā pūrua ko X1B, X2B, X3B mō ngā hononga ā-wāhanga, X1A, X2A, me X3A mō ngā hononga kūpapa. Mō te hononga Delta 2400V, ko ngā pūrua e whai ake nei: C1B ki X2A, X2B ki X3A, me X3B ki X1A.
    24

    24.94 kV 2550 kVA Whakawhiti
    Kua hangaia ngā whakawhiti hiko katoa e mau ana ki te papa 2550 kVA o tēnei raupapa kia tutuki ai te paerewa IEEE C57.12.34, e whakamana ana i te kounga me te mahi tino pai. Kei a rātou he hoahoa korokoro taha-mau mō te hononga ngaohiko-iti, e taea ai te whakauru maeneene ki te taputapu whakawhiti. Hei tāpiri, ko te pana wehenga-kawenga mō ēnei whakawhiti hiko 2550 kVA kua hoahoatia marietia i roto i te rūma pēhanga-iti o te kāpata o mua, e tuku ana i ngā tūranga e whā mō te ngāwari. E whakarato ana te taputapu whakawhiti tap i ngā tūranga e rima, ā, kua whakatakotoria te taputapu whakatikatika pēhanga ki te 24.94±2×2.5% mō te whakahaere tika. Ko te aukati o ēnei whakawhiti hiko i te 85°C he 5.87%, e whakarite ana i te mahi pumau me te whai hua. Hei tāpiri, ko ā rātou Taumata Whakamarumaru Taketake ngaohiko-tiketike me te ngaohiko-iti (BIL) kua whakatauria ki te 125kV me te 30kV, ia, kia whakarite ai i te mahi whakamahana pakari.

    Uiui Inaianei!

    Mō ngā pātai e pā ana ki ā mātou hua, ki te rārangi utu rānei, waiho mai tō īmēra ki a mātou, ā, ka whakapā atu mātou i roto i ngā haora 24.

    Leave Your Message