+86 18068001229 01
Whakawhiti Pou Kotahi-Wāhanga—50kVA
Whakaahuatanga Hua
Ko te whakawhiti hiko 50 kVA kotahi-wāhanga a te JZP Transformer kua whakamanahia ki te rārangi UL me te tautokona e te pūrongo tirotiro CESI. Me te whānuitanga o ngā ngaohiko o te 2.4-34.5kV, ka piri te whakawhiti hiko ki ngā paerewa o te ao pēnei i te ANSI, IEEE, CSA, IEC, me te DOE, kia whakarite ai i te hototahitanga me te mahi o te ao. Mā te whakamahi i ngā tau 20 o te tohungatanga ki te hoahoa me te kaweake, kua rite te tīma Whakawhiti JZP ki te whakatutuki i ngā whakaritenga rerekē, me te tuku otinga whakaritenga mō ngā whakawhiti hiko motuhake. Me te whakapau kaha ki te makona me te kounga o te kiritaki, ka tukuna e JZP Transformer ngā hua pono, whai hua, me te haumaru hei whakatutuki i ngā hiahia ahurei o ngā kiritaki puta noa i te ao.

13.8 kV 50 kVA Whakawhiti Pou Whakamau
Ko te D-50-13.8/0.12-0.24kV, he whakawhiti hiko 50 kVA te kaha, he mea hanga tino ātaahua e JZP Transformer, e tutuki ana i ngā paerewa IEEE C57.12.20. Me te kaha o te 50kVA, ka mahi i te 13.8 kV i te taha tuatahi, ā, ka whakarato i te 120/240V i te taha tuarua. E rua ngā pūngao hiko teitei o te whakawhiti hiko, e toru ngā pūngao hiko iti, me ngā pūmau e rua hei whakarei ake i te mahi me te haumaru.
Ka whakamanahia e JZP Transformer te kounga me te pono o ia waeine. Kua hangaia ngā transformer kia tutuki ai ngā whakaritenga ahurei o te whatunga tohatoha hiko o Guyana, kia pai ai te tuku hiko, kia pumau hoki. Me te whakapau kaha ki te makona o ngā kiritaki, ka tukuna e JZP Transformer ngā hua tino pai me te ratonga tino pai hei whakatutuki i ngā hiahia o te kamupene hiko i Guyana.

14.4 kV 50 kVA Whakawhiti Wāhanga Kotahi
Ko te D-50-14.4/0.12-0.24 te whakawhiti hiko kotahi-wāhanga 50 kVA e mau ana ki te pou. Ka mahi i te 24940/14400V (ngaohiko teitei) me te 120/240V (ngaohiko iti) me te pūnga HV kotahi. He takai konumohe te whakawhiti hiko e tutuki ana i ngā paerewa whai hua CSA C2.1 me CSA 802.1. Ka rere i te 60Hz, ā, he pūnaha whakamatao ONAN. He whakamarumaru Akomanga A te whakawhiti hiko.

Whakawhitihiko Wāhanga Kotahi 16/27.6kV 50 kVA
Ko te D-50-16-27.6kV/347(600Y)V he whakawhiti hiko motuhake 50 kVA, he mea hanga motuhake mō ngā tono motuhake. E mahi ana i ngā taumata ngaohiko teitei o te 16kV me te 27.6kV, ā, e whakarato ana i te ngaohiko iti i te 347(600Y)V.
I hoahoatia, i hangaia hoki e JZP Transformer, ā, e piri ana ki ngā paerewa CSA C802.1 me CSA C2.1, kia pai ai te mahi me te haumaru. E rua ngā kōwhiringa ngaohiko teitei e tukuna ana e te transformer: 16,000V me te 27,600V, kia maha ai ngā whakamahinga mō ngā momo horopaki tohatoha hiko. Kei roto ko te pūnga ngaohiko teitei, ngā pūnga ngaohiko iti e rua, me te pana ngaohiko takirua hei ngāwari i te whiriwhiri ngaohiko.
Ko ngā āheinga ahurei o tēnei whakawhiti hiko takirua-ngaohiko 50kVA kotahi-wāhanga e whakatutuki ana i ngā hiahia hiko motuhake o te rohe, e whakarite ana i te tuku hiko pono me te tutuki i ngā paerewa ahumahi teitei rawa atu.

Whakawhitihiko Wāhanga Kotahi 2.4kV 50 kVA
Ko te D-50-2.4kV/120(240)V he whakawhiti hiko 50 kVA e mau ana ki te pou, he wāhanga kotahi, kei roto he ngaohiko teitei 2.4 kV me te ngaohiko iti 120V, he mea whakarite motuhake mō tētahi kiritaki Kanata. Kei ia whakawhiti hiko tētahi pūnga ngaohiko teitei me ētahi pūnga ngaohiko iti e toru, e arotau ana i te hononga. He mea hoahoa me te hanga āta, ka tutuki i ēnei whakawhiti hiko ngā paerewa CSA pakari, e whakarite ana i te mahi tino pai me te haumaru. Me te whakapau kaha ki te hiranga, kua whakaritea ēnei whakawhiti hiko kia tutuki ai ngā hiahia motuhake o te kiritaki Kanata, e whakarato ana i te tohatoha hiko pono me te whai i ngā ture ahumahi katoa e tika ana.

Uiui Inaianei!
Mō ngā pātai e pā ana ki ā mātou hua, ki te rārangi utu rānei, waiho mai tō īmēra ki a mātou, ā, ka whakapā atu mātou i roto i ngā haora 24.









