+86 18068001229 01
Ngā Otinga Whakawhiti Hiko Ritenga≤2500 kVA
Ngā tawhā hua
| Momo | Te kaha | Taumata Ngaohiko | Whakamatao | Tono |
| Whakawhiti Tohatoha | 1,600 kVA | 11 kV / 400 V | TAIOHI | Whare noho/ahumahi |
| Whakawhiti Mana | 500 MVA | 220 kV / 33 kV | OFAF | Pūnaha tuku ā-rohe |
| Whakawhiti UHVDC | ±400 kV / 500 MVA | ±800 kV HVDC | Hinu whakakaha | Ngā whatunga ā-motu |
| Whakawhiti Whakatikatika | 20 MVA | 33 kV / 1.8 kV × 6-pānga | Momo-maroke, whakamatao-hau | Te hikohiko o te konumohe |







whakaahuatanga hua
1. Te Kaha Whakatauranga (MVA/kVA)
Whakamāramatanga: Te putanga mana tonu mōrahi ka taea e te whakawhiti hiko te tuku.
Awhe Noa:
Ngā Whakawhiti Tohatoha: ≤2,500 kVA (hei tauira, te tohatoha hiko mō ngā whare noho, mō ngā whare ahumahi rānei).
Ngā Whakawhiti Hiko: Ngā mano o te kVA ki ētahi GVA (hei tauira, ngā teihana whakawhiti hiko).
Ngā Whakawhiti Hiko Tino-Teitei (UHV): Mō te hononga whatunga, mō te whakamahinga ahumahi rānei, tae atu ki te ±800 kV ngā whakawhiti hiko HVDC.
;2. Whakatauranga Ngaohiko
Ngā Ngaohiko Tāuru/Taputanga:
Ngaohiko Teitei (HV): I te nuinga o te wā 33 kV ki te ±1,100 kV (hei tauira, ngā whatunga tuku).
Ngaohiko Waenga (MV): Noa 11 kV, 22 kV, 33 kV.
Ngaohiko Iti (LV): Ko te tikanga he 400 V, he 6.6 kV rānei (ka tohatoha ki ngā kaiwhakamahi mutunga).
Ngā Whakamahinga Motuhake:
Ngā Whakawhiti Whakatikatika: Mō te mahi whakarewa/matū, ngā ngaohiko tae atu ki te 30 kV+.
Ngā Whakawhitiwhiti Kume Rerewē: I whakarerekētia mō te mana o te waka tereina, hei tauira, 27.5 kV, 1×25 kV rānei.
;
3. Auautanga
Paerewa: 50 Hz (Haina/Ūropi) 60 Hz rānei (Amerika ki te Raki).
Auautanga Motuhake: 400 Hz mō ngā tono rererangi/moana.
;4. Pūnaha Whakamatao
Kua rukuhia ki te hinu:
ONAN (Hinuhinu Taiao, Hau Taiao): Whakamatao ā-kaweka taiao.
ONAF (Hinuhinu Taiao Ā-Hau Whakahau): Whakamatao hau whakahau kia pai ake ai te mahi.
Momo Maroke: He hau-whakamatao, he pai mō ngā wāhi o roto/ngā wāhi tairongo ki te ahi (hei tauira, ngā pokapū raraunga).
Whakamarumaru-Hau (GIS): Whakamarumaru hau SF6, hoahoa kiato mō ngā teihana hiko kiato-teitei.
;5. Momo Whakamarumaru
Rukuhia ki te Hinu: Hinu kohuke, hinu rānei kei roto i te ester (he pai mō te taiao).
Momo-Maroke: Whakamaroke i hangaia ki te kapia epoxy, ki te pepa Nomex rānei (ātete ahi/pahū).
Whakamarumaru-Hau: SF6, ngā hau whakauru rānei (ngā teihana hiko kiato ngaohiko teitei).
;6. Te Whai Hua
Ngā Uara Noa:
Ngā Whakawhiti Tohatoha: ≥98% (he iti ngā ngaronga kore-kawenga me ngā ngaronga kawenga).
Ngā Whakawhiti Hiko: ≥99% (he nui ake te pai o ngā tauira ngaohiko tino teitei).
Paerewa: Kia tutuki ki te IEC 61620, ki te IEEE C57.12 rānei (hei tauira, ngā whakaritenga hoahoa taiao a te EU).
;7. Rōpū Hononga
Rerekētanga Āhuatanga: I tautuhia ko Dyn11, Yd11, e tohu ana i ngā whanaungatanga ā-wāhanga i waenga i ngā takai hei whakahaere i ngā harmonika me ngā iahiko porowhita-poto.
;8. Ngaohiko Ārai
Whakamāramatanga: Te ōrau o te hekenga ngaohiko i te wā whakamātautau ara-poto, e whakaatu ana i te kaha ki te tu atu ki te ara-poto.
Ngā Uara Noa: 4–10% (ngā whakawhiti hiko), ≤4% (ngā whakawhiti tohatoha).
;9. Te Pikinga o te Pāmahana
Ngā Here: Ko ngā whakawhiti hiko kua rumakina ki te hinu ka taea te piki ake te pāmahana ≤55 K (te hinu o runga i te 40°C taiao).
Te Urutau ki te Taiao: Me nui ake te whakahekenga pāmahana e hiahiatia ana mō ngā rohe koraha.
;10. Whakatauranga Tiakitanga
Ngā Waehere IP:
IP23: He rehu ātete-wai, he pare-pūngao-ki-te-pūngao.
IP66/IP68: Hiri katoa ki te puehu/wai (ngā tono moana/whenua).
Taiao Motuhake: Ātete ki te waikura o te rehu tote mō te whakamahinga i te takutai moana/i raro i te moana.
11. Ngā Momo Motuhake
Ngā Whakawhiti Whakatikatika: Ngā hoahoa maha-pānga (hei tauira, 12/24-pānga) hei whakaiti i ngā harmonika.
Ngā Whakawhiti Huri-Tāpiri: Ngā whakawhiti tap kei runga-uta (OLTC) hei whakahaere i te ngaohiko.
Ngā Whakawhiti Motuhake:
Ngā Whakawhiti Umu Hiko: I hangaia mō te taumahatanga wā poto (hei tauira, te whakarewa maitai).
Ngā Whakawhitiwhiti Kōpikopiko: Ngā pūnaha whenua kūpapa mō te pehi i te haruru.
Momo Te Kaha Taumata Ngaohiko Taupānga Whakamatao
Whakawhiti Tohatoha 1,600 kVA 11 kV / 400 V ONAN Whare noho/ahumahi
Pūwhakawhiti Hiko 500 MVA 220 kV / 33 kV OFAF Pūnaha Tuku Rohe
Pūwhakawhiti UHVDC ±400 kV / 500 MVA ±800 kV HVDC Hinu Āwhina Ngā whatunga whakawhiti whenua
Whakawhiti Whakarerekē 20 MVA 33 kV / 1.8 kV × 6-pāhi Konumohe hiko-whakamatao-hau, momo-maroke



He aha mātou i whiriwhiri ai
Ko JIEZOU POWER he kaihoahoa, he kaihanga me te tāuta ngaio o te otinga pūnaha hiko huri noa i te ao, i whakatūria i te tau 1989, ā, e 200,000 mita tapawha te rahi o te whenua e noho ana.
Ko JIEZOU POWER te kaiwhakahaere matua o ngā kaupapa whatunga hiko, te 500KV EPC, te tipu hiko wai 230KV, te teihana hiko 115KV, me ētahi atu.
Ka taea e te wheketere o JIEZOU POWER te hanga i ngā whakawhiti hiko momo hinu me te momo maroke, te whakawhiti hiko mōrahi 500KV 480MVA, GIS, taputapu whakawhiti, teihana hiko iti, i runga i te paerewa ANSI/IEEE/DOE2016/CSA/IEC60076.
Kua whiwhi a JIEZOU POWER i ngā tiwhikete ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, me te PŪRONGOTANGA WHAKAMĀTAUTAU MOMO. Tae noa ki te tau 2023, kua tohatohahia ngā kamupene peka me ngā wheketere o te ao ki te Hononga o Amerika, Kanata, Dubai, Dominican Republic, Philippines, ā, kei te tāone o BengBu, te tāone o FengYang, te tāone o HaiAn, te tāone o TaiZhou, te tāone o SuZhou, te tāone o ShenYang, me te tāone o FoShan ngā wheketere me ngā kamupene peka o Haina.
I te tirohanga whakamua, ko te moemoeā a JIEZOU POWER kia noho hei kaiwhakarato otinga pūnaha hiko tino pono, kia whakaoti i ngā wero whakahaere hiko tino nui o te ao, kia tere ake te whakawhiti o te ao ki te pūngao hou. Kia taea ai e te katoa te whai oranga iti-waro me te kanapa. Hei whakatutuki i tēnei, ka whakapau kaha mātou.



Uiui Inaianei!
Mō ngā pātai e pā ana ki ā mātou hua, ki te rārangi utu rānei, waiho mai tō īmēra ki a mātou, ā, ka whakapā atu mātou i roto i ngā haora 24.